Product Overview:
Triggering Modes
There are five different methods that can be used to scan barcodes:
1. Software Trigger
In this mode a software command is used to trigger the ICR803. The
command structure is as follows:
[SYN] T [CR] To Trigger (Scanner LED’s will turn on and scan
barcode. After scanning the LED’s will turned
back off.)
[SYN] U [CR] To Turn off Triggering of scanner (only needed
if the scanner hasn’t scanned a barcode).
2. Button Trigger
The IC803 has an integrated button that is useful for manually triggering
the scanner.
3. Hardware Trigger
The ICR803 can be externally triggered via a hardware line (Rev C of product
and above). The external trigger is active low. When pin 1 on the modular
connector is low the ICR803 will turn on and start scanning. The ICR803 will
turn off if the trigger line goes high or if a barcode is decoded (whichever
happens first).
To Trigger Manually:
Press Button on Side
SICK AG