Página 1

ICR 803 Bar Code Scanner BAR CODE MANUAL

Página 2 - Plug and Play Bar Codes

ICR803 Bar Code Manual – Rev A – 04/2007 - 10 - User-Specified Good Read Delay If you want to set your own length for the good read delay,

Página 3 - USB COM Port Emulation

ICR803 Bar Code Manual – Rev A – 04/2007 - 11 - Manual Trigger, Low Power The imager powers down until the trigger is pulled. When the tri

Página 4

ICR803 Bar Code Manual – Rev A – 04/2007 - 12 - Presentation Mode This programs the imager to work in Presentation mode. The LEDs are eith

Página 5

- 13 - LED Power Level This selection allows you to adjust LED and aimer brightness. Off is used when no illumination is needed. Low is used if

Página 6

- 14 - Imager Time Out Imager Time Out powers down the imager after the unit has been idle for the specified time. To prevent the imager from powe

Página 7 - Good Read Indicators

- 15 - Centering Use Centering to narrow the imager’s field of view to make sure the imager reads only those bar codes intended by the user. For

Página 9 - Reread Delay

- 17 - Decode Search Mode There are three selectable decode (scanning) modes: Full Omnidirectional (default) - Searches for bar code features b

Página 10 - Trigger Modes

- 18 - Output Sequence Overview Require Output Sequence When turned off, the bar code data will be output to the host as the Imager decodes it. W

Página 11 - Scan Stand Symbol

- 19 - Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the imager to output Code

Página 12 - Hands Free Time Out

ICR803 Bar Code Manual – Rev A – 04/2007 - 2 - Using This Manual This manual contains bar codes used to program the ICR803. For initial set

Página 13 - Illumination Lights

- 20 - Output Sequence Editor Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence o

Página 14 - Imager Time Out

- 21 - Multiple Symbols Note: This feature does not work when the Imager is in Low Power mode. When this programming selection is turned On, it a

Página 15 - Centering

- 22 - Print Weight Print Weight is used to adjust the way the imager reads Matrix symbols. If a imager will be seeing consistently heavily prin

Página 17 - Decode Search Mode

- 24 - Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar cod

Página 18 - Output Sequence Overview

- 25 - To add a backslash (\), scan 5, C, 5, C. Note: To add a backslash (\) as in Step 7, you must scan 5C twice – once to create the leading bac

Página 19 - Output Sequence Example

- 26 - Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the imager transmits the

Página 20 - Require Output Sequence

- 27 - Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Inte

Página 21 - No Read

- 28 - Interfunction Delay An interfunction delay of up to 495 milliseconds may be placed between the transmission of each segment of the messag

Página 22 - Video Reverse

- 29 - Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the imager’s output. For example, you can us

Página 23

ICR803 Bar Code Manual – Rev A – 04/2007 - 3 - USB COM Port Emulation Scan the following code to program the USB version of the ICR803 to em

Página 24 - Data Editing

- 30 - Other Programming Selections • Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary form

Página 25

- 31 - count of the number of suppressed characters in the list and xxyy .. zz is the list of characters to be suppressed. (xx stands for the hex v

Página 27 - Intercharacter Delay

- 33 - Symbologies This programming section contains the following menu selections.

Página 28 - Intermessage Delay

- 34 - All Symbologies If you want to decode all the symbologies allowable for your imager, scan the All Symbologies On code. If on the other han

Página 30 - Data Format Editor Commands

- 36 - Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the imager looks for a Codabar symbol having a

Página 31

- 37 - Codabar Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Ma

Página 33 - Symbologies

- 39 - Code 39 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 0-48. Minimum Default = 0, M

Página 34 - All Symbologies

ICR803 Bar Code Manual – Rev A – 04/2007 - 4 -

Página 35

- 40 - Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also

Página 36 - Codabar Concatenation

- 41 - FULL ASCII Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single ch

Página 37 - Codabar Message Length

- 42 - Interleaved 2 of 5 (or I 2 of 5) Check Digit No Check Digit indicates that the imager reads and transmits bar code data with or wit

Página 38

- 43 - Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 2-80. Minimum Defau

Página 39 - Code 39 Append

- 44 - Code 93 Code 93 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 0-80. Minimum Defaul

Página 40

- 45 - Code 2 of 5 Code 2 of 5 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-48. Mini

Página 41 - FULL ASCII

- 46 - IATA Code 2 of 5 IATA Code 2 of 5 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1

Página 42

- 47 - Matrix 2 of 5 Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-80.

Página 43

- 48 - Code 11 Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digi

Página 44 - Code 93

- 49 - Code 128 ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating cri

Página 45 - Code 2 of 5

ICR803 Bar Code Manual – Rev A – 04/2007 - 5 -

Página 46 - IATA Code 2 of 5

- 50 - Code 128 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Ma

Página 47 - Matrix 2 of 5

- 51 - Telepen Telepen Output Using AIM Telepen Output, the imager reads symbols with start/stop pattern 1 and decodes them as standard full

Página 48 - Code 11

- 52 - UPC-A UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data

Página 49 - Code 128

- 53 - UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda.

Página 50 - Code 128 Message Length

- 54 - UPC-E0 UPC-E0 Expand

Página 51 - Telepen Message Length

- 55 - UPC-E0 Addenda Required When Addenda Required is set to on, the imager will only read UPC-E bar codes that have addenda. Default = Not Requ

Página 52

- 56 - EAN/JAN-13

Página 54 - UPC-E0

- 58 - ISBN Translate This selection causes EAN-13 Bookland symbols to be translated into their equivalent ISBN number format. Default = Off. EA

Página 56 - EAN/JAN-13

ICR803 Bar Code Manual – Rev A – 04/2007 - 6 -

Página 62

- 65 - Code 49 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-81. Minimum Default = 1,

Página 63

- 66 - PDF417 PDF417 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-2750. Minimum Defau

Página 64

- 67 - MicroPDF417

Página 65 - Code 49 Message Length

- 68 - UPC/EAN Version Scan the UPC/EAN Version On bar code to decode EAN•UCC Composite symbols that have a UPC or EAN linear component. (This do

Página 66 - PDF417

- 69 - EAN•UCC Emulation The imager can automatically format the output from any EAN•UCC data carrier to emulate what would be encoded in an equiv

Página 67 - MicroPDF417

ICR803 Bar Code Manual – Rev A – 04/2007 - 7 - Good Read Indicators

Página 68 - UPC/EAN Version

- 70 - Postal Symbologies Postal Codes Note: For best performance when reading a postal symbology, all other postal symbologies should be turned

Página 70 - Postal Codes

- 72 - China Post China Post Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 0-80. Minimu

Página 71

- 73 - Korea Post Korea Post Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 2-80. Minimum

Página 72 - China Post

- 74 - 2D Matrix Symbologies QR Code QR Code Message Length Scan the bar codes below to change the message length. Minimum and

Página 73 - Korea Post

- 75 - Data Matrix Data Matrix Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-1500. Mini

Página 74 - QR Code

- 76 - MaxiCode MaxiCode Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-150. Minimum De

Página 75 - Data Matrix

- 77 - Aztec Code Aztec Code Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-3750. Mini

Página 76 - MaxiCode

- 78 - OCR Programming

Página 77 - Aztec Code

- 79 - OCR Default All OCR Settings turns off all OCR capability in the imager, so the imager will be able to scan linear, stacked, matrix, and co

Página 78 - OCR Programming

ICR803 Bar Code Manual – Rev A – 04/2007 - 8 - .

Página 79

- 80 - U.S. Currency U.S. Currency On allows you to scan characters in the font used on U.S. currency. The default setting allows you to scan any 8

Página 80 - SEMI Font

- 81 - Creating OCR Templates You can create a custom “template,” or character string that defines the length and content of OCR strings that will

Página 81 - Creating OCR Templates

- 82 - } hex codes for letters A, B, and C To create this template, you would scan the Enter OCR Template symbol, scan the d from the Sample Sym

Página 82

- 83 - 9902XZ50 You can string together as many templates as you need. Creating a User-Defined Variable You can create up to two of your own use

Página 83 - Reading Multi-Row OCR

- 84 - Adding an OCR Check Character You may want to print and verify a check character in order to enhance the security of your OCR applicatio

Página 84

- 85 - OCR Modulo 36 Character Set Scan this symbol to program the OCR template for a simple modulo 36 checksum of the digits 0 through 9 and the

Página 85 - Exit Selections

- 86 - To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbol

Página 86

- 87 - Test Menu When you scan the Test Menu On code, then scan a programming code in this manual, the imager displays the content of a programming

Página 87 - Quick*View

- 88 - APPENDIX A: Symbology Chart Symbology AIM ID Possible AIM ID Modifiers (m) HHP Code ID (hex) All Symbologies (0x99) Australian Pos

Página 88 - APPENDIX A: Symbology Chart

- 89 - Plessey Code ]P0 n (0x6E) PosiCode ]pm 0, 1, 2 W (0x57) Postnet ]X0 P (0x50) QR Code ]Qm 0-6 s (0x73) Reduced Space Symb

Página 89

ICR803 Bar Code Manual – Rev A – 04/2007 - 9 - Reread Delay This sets the minimum amount of time before the imager can read the same bar co

Página 90

- 90 - APPENDIX B: ASCII Conversion Chart Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char 0 00 NUL 32

Página 91 - APPENDIX C – Sample Symbols

- 91 - APPENDIX C – Sample Symbols

Página 93

- 93 - APPENDIX D – Programming Charts

Página 94

- 94 - APPENDIX D – Programming Charts

Página 95

- 95 - APPENDIX D – Programming Charts

Página 96

SICK AG | Waldkirch | Germany | www.sick.com8012076/2007-04 ∙ HaWa <PM6.5/Word/PDF>/VD ∙ Printed in Germany ∙ Subject to change without no