SICK ICR803 Manual de Início Rápido Página 31

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 96
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 30
- 31 -
count of the number of suppressed characters in the list and xxyy .. zz is the list of characters to be
suppressed. (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Appendix B)
FC Disables suppress filter and clear all suppressed characters. Syntax = FC.
E4 Replaces up to 15 characters in the data string with user specified characters. Replacement continues
until the E5 command is encountered. Syntax = E4nnxx
1
xx
2
yy
1
yy
2
...zz
1
zz
2
where nn is the total count
of both characters to be replaced plus replacement characters; xx
1
defines characters to be replaced
and xx
2
defines replacement characters, continuing through zz
1
and zz
2
.
E5 Terminates character replacement. Syntax = E5.
FE Compare character in current cursor position to the character “xx.” If characters are equal, increment
cursor. If characters are not equal, no format match. Syntax = FExx (xx stands for the hex value for an
ASCII code, see ASCII Conversion Chart (Appendix B).
EC Check to make sure there is an ASCII number at the current cursor position. If character is not numeric,
format is aborted. Syntax = EC.
ED Check to make sure there is a non-numeric ASCII character at the current cursor position. If character
is numeric, format is aborted. Syntax = ED.
Vista de página 30