Operating Instructions Chapter 8
CLV490 Bar Code Scanner
8009993/RA61/2007-07-20 © SICK AG · Division Auto Ident · Germany · All rights reserved 8-9
Troubleshooting
8.5 Troubleshooting
The following are required for troubleshooting purposes using the tables below:
These Operating Instructions
Tools
A tape measure (up to 3 m (9.84 ft))
A digital measuring device (current/voltage measurement)
A PC running CLV-Setup
A 3-core RS 232 data cable (null modem cable), pins 2 and 3 crossed,
e. g. no. 2014054
8.5.1 General malfunctions: CLV490 not ready
Malfunction Possible cause Remedy
The "Device Ready" LED is not lit.
The "Result 1" output is not outputting a
pulse (default setting: Device Ready)
After switching on the power supply:
The CLV490 has no power.
The CLV490 has diagnosed a device er-
ror during the self-test.
During operation:
The CLV490 is not in "Reading" mode.
The CLV490 has deactivated the laser
diode 10 min. (default setting) after the
start of the current reading pulse (trigger
mode: sensor input/serial interface).
Check wiring (power connector fitted
securely to the CDM490 Connection
Module).
Measure voltage at pin 1 and pin 5.
Switch CLV490 off and on again. Does
the LED light up? If not, contact SICK Ser-
vice department
Return to Reading mode using the "CLV-
Setup" program. See Chapter 6.5.1
Reading mode (standard operating
mode), Page 6-38
Terminate reading pulse.
Check the reading pulse function. Supply
new pulse. See Table 6-23, Page 6-36.
Table 8-5: Troubleshooting: restoring operation (Reading mode)