Chapter 6 Operating Instructions
CLV490 Bar Code Scanner
6-14 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Operation
Note At a scanning frequency of 1,000 Hz, the typical response time for focus adjustment is
20 ms, or 30 ms if the entire range (between min. and max. focus position) is traversed.
The CLV490 does not switch over the focus until the defined timeout has elapsed and the
new focus position exceeds the parameterized hysteresis value relative to the old focus
position. If the new focus position is within the hysteresis, the CLV490 does not switch over
the focus.
Depth-of-field optimization with respect to the object and the purpose of depth-of-field
optimization are described in Chapter 3.2.1 Autofocus function, Page 3-7.
2. Configure autofocus Additionally for autofocus mode "Differential background“
and „Differential background and tracking“:
Ö AUTOFOCUS SPACE section
Right edge of conveyor (Y 1)
Left edge of conveyor (Y 2)
Level of conveyor (Z 1)
Maximum scanning height (Z 2)
Ö AUTOFOCUS OPTIMIZATION PARAMETERS button
Ö DELAY OF FOCUS CHANGE section
–Timeout
–Hysteresis
Ö DEPTH OF FIELD OPTIMIZATION section
Offset at minimum
Offset at maximum
Ö "Distance measurement" section (default setting)
active
Source of distance information: internal/external
Smooth filter: active, length 3
3. Teach-in background
(optional)
For autofocus mode "Differential background“ and „Differential
background and tracking“:
Ö Menu CLV490
Ö DEVICE FUNCTIONS
Ö Background
–Teach-in
Check taught-in background:
Ö READING CONFIGURATION tab
Ö AUTOFOCUS section
Ö SHOW BACKGROUND
2)
button
Displaying online the actual background profile with focus level
points:
Ö Menu CLV490
Ö BACKGROUND ANALYSIS
Analysis: Autofocus
4. Select focus position
switchover (refered to the
start of the reading interval)
Ö READING CONFIGURATION tab
Ö FOCUS CONTROL section
Ö INPUTS/SERIAL/AUTOFOCUS
immediate or synchronous (default setting) or
–latched
2) The CLV490 displays the taught-in background with the internal correction of 100 mm (3.9 in) but not the parameterized
limits of the autofocus space.
Action Settings in CLV-Setup
Table 6-6: Guide: Configuring the autofocus function (part 1) (contd.)