Operating Instructions Chapter 4
CLV490 Bar Code Scanner
8009993/RA61/2007-07-20 © SICK AG · Division Auto Ident · Germany · All rights reserved 4-1
Installation
4 Installation
4.1 Installation sequence
Change the language version of the laser warning label (if necessary)
Select the mounting location for the CLV490
Mount the CLV490 and align the CLV490 with the bar code
Mount the CDB420 or CDM490 Connection Module
Connect the CLV490 to the CDB420 or CDM490 Connection Module
Adjust the CLV490 so that it is in line with the bar code
Mount the reading pulse sensor for external triggering the reading pulse
Option with event-controlled dynamic focus control:
mount the sensors for detecting the object distance
Note Don’t open the device. The warranty will be forfeited if the device is opened.
4.2 Preparations
4.2.1 Required components
CLV490 Bar Code Scanner
4.2.2 Required accessories
SICK mounting bracket for the CLV490: depending on the order, angle bracket
no. 2013824, articulated bracket no. 2018435, angle bracket no. 2022996, or quick-
clamping device no. 2016110 with securing material for the CLV490
– or –
Alternatively, if the bracket is supplied by the user
Stable mounting device that allows the alignment of the CLV490 to be varied in the
x and y axes. The weight of the CLV490 (line scanner) is 1.5 kg (3.3 lb) and 2.2 kg
(4.84 lb) as a line scanner with oscillating mirror.
2 screws M6 for the CLV490. The screw length depends on the wall thickness of the
bracket used. Depth of engagement in CLV490 max. 7 mm (0.28 in) from housing
surface.
CDB420 or CDM490 Connection Module (not included in the scope of supply of
the CLV490)
Reading pulse sensor for external reading pulse triggering, e. g. photoelectric reflex
switch/ photoelectric proximity switch (not included in the scope of supply of the
CLV490)
Option with event-controlled dynamic focus control: sensors for detecting the object
distance, e. g. photoelectric reflex switches/photoelectric proximity switches (not
included in the scope of supply of the CLV490)
Optionally for internal tracking: an incremental encoder (not included in the scope of
supply of the CLV490)
4.2.3 Required auxiliary parts
2 screws M6 for securing the SICK mounting bracket to the base. The screw length
depends on the wall thickness of the base.
Set of laser warning labels (if necessary)
Tool