Chapter 10 Operating Instructions
CLV 490 Bar Code Scanner
10-60
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 008 796/0000/25-06-2002
Appendix
Set the following parameters on the O
PTIMIZATION
tab (
Fig. 10-48
)
Delay of focus change
Timeout: 50 ms
Hysteresis: 50 mm
Distance Measurement: active
Source of Distance information: internal
Smooth filter active: active Length: 3
Confirm the dialog window by clicking "OK".
2. Setting up the autofocus function (Part 2): D
EVICE
C
ONFIGURATION
tab
Fig. 10-48: Parameterization example: "Edit Auto Focus/Optimizations" dialog window
Fig. 10-49: Parameterization example: Buttons on the "Device Configuration" tab