Operating Instructions Chapter 5
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-9
Electrical installation
5.4.3 Non-SICK Power supply unit/connections without the Connection Module
Power output
If an non-Sick Power supply unit is used instead of the AMS 60, it must be capable of
providing the following voltage and power values:
•
For CLV without heater: 18 ... 30 V DC, min. 20 W continuous power output
•
For CLV with heater: 24 V DC +20 %/–10 %, min. 100 W
The non-Sick Power supply unit must comply with IEC 742 (functional extra-low voltage).
The output circuit must be reliably electrically isolated from the input circuit pursuant
to IEC 742 by means of double insulation and a safety isolating transformer.
Wire cross-section
The wire cross-section for the power supply (Pin 1/Pin 5) should be at least 0.15 mm
2
, or
0.75 mm
2
for CLVs with heater, with a max. length of 10 m.
a) Connecting the CLV without a connector cover/external parameter memory
The two cables no. 2 020 303 and no. 2 020 264 with open cable end on one side are
required to connect the CLV. The wire color assignments are shown in
Table 5-10
and
Table5-11, Page5-10.
The cables must not be extended for CLVs with heater.
Connection cable no. 2 020 203 ("Host/Term" connection)
15-pin D Sub HD socket and open cable end
Pin Signal Wire color
1
1)
V
S
Red
2 RxD (RS 232), Terminal White
3 TxD (RS 232), Terminal Brown
4 Term (RS 422/485) Violet
5 GND Blue
6 RD+ (RS 422/485), Host Green
7 RD– (RS 422/485), Host
RxD (RS 232), Host
Yellow
8 TD+ (RS 422/485), Host Grey
9 TD– (RS 422/485), Host
TxD (RS 232), Host
Pink
10 CAN H –
11 Bus RT_485– –
12 Bus RT_485+ –
13 Bus R_485– –
14 Bus R_485+ –
15 CAN L –
–
Shield Orange
1) Pin 1 is jumpered with Pin 1 of the "I/O" connection in the CLV
Table 5-10: Wire color assignment of the cable no. 2 020 303